Papers
Topics
Authors
Recent
Search
2000 character limit reached

Flight Performance of an advanced CZT Imaging Detector in a Balloon-borne Wide-Field Hard X-ray Telescope - ProtoEXIST1

Published 27 Jul 2011 in astro-ph.IM | (1107.5573v1)

Abstract: We successfully carried out the first high-altitude balloon flight of a wide-field hard X-ray coded-aperture telescope ProtoEXIST1, which was launched from the Columbia Scientific Balloon Facility at Ft. Sumner, New Mexico on October 9, 2009. ProtoEXIST1 is the first implementation of an advanced CdZnTe (CZT) imaging detector in our ongoing program to establish the technology required for next generation wide-field hard X-ray telescopes. The CZT detector plane in ProtoEXIST1 consists of an 8 x 8 array of closely tiled 2 cm x 2 cm x 0.5 cm thick pixellated CZT crystals, each with 8 x 8 pixels, covering a 256 cm2 active area with 2.5 mm pixels. A tungsten mask, mounted at 90 cm above the detector provides shadowgrams of X-ray sources in the 30 - 600 keV band for imaging, allowing a fully coded field of view of 9 Deg x 9 Deg with an angular resolution of 20 arcmin. To reduce the background radiation, the detector is surrounded by semi-graded (Pb/Sn/Cu) passive shields on the four sides all the way to the mask. On the back side, a 26 cm x 26 cm x 2 cm CsI(Na) active shield provides signals to tag charged particle induced events as well as >~ 100 keV background photons from below. The flight duration was only about 7.5 hours due to strong winds (60 knots) at float altitude (38-39 km). Throughout the flight, the CZT detector performed excellently. The telescope observed Cyg X-1 for ~ 1 hour at the end of the flight. Despite a few problems with the pointing and aspect systems that caused the telescope to track about 6.4 deg off the target, the analysis of the Cyg X-1 data revealed an X-ray source at 7.2 sigma in the 30-100 keV energy band at the expected location from the optical images taken by the onboard daytime star camera. The success of this first flight is very encouraging for the future development of the advanced CZT imaging detectors (ProtoEXIST2, with 0.6 mm pixels).

Summary

No one has generated a summary of this paper yet.

Paper to Video (Beta)

No one has generated a video about this paper yet.

Whiteboard

No one has generated a whiteboard explanation for this paper yet.

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Continue Learning

We haven't generated follow-up questions for this paper yet.

Collections

Sign up for free to add this paper to one or more collections.