Papers
Topics
Authors
Recent
Search
2000 character limit reached

A joint analysis of Planck and BICEP2 B modes including dust polarization uncertainty

Published 22 May 2014 in astro-ph.CO, gr-qc, hep-ph, and hep-th | (1405.5857v2)

Abstract: We analyze BICEP2 and Planck data using a model that includes CMB lensing, gravity waves, and polarized dust. Planck dust polarization maps have highlighted the difficulty of estimating the dust polarization in low intensity regions, suggesting that the polarization fractions have considerable uncertainties and may be significantly higher than previous predictions. In this paper, we start by assuming nothing about the dust polarization except for the power spectrum shape, which we take to be $C_{l}{BB} \propto l{-2.42}$. The resulting joint BICEP2+Planck analysis favors solutions without gravity waves, and the upper limit on the tensor-to-scalar ratio is $r<0.11$, a slight improvement relative to the Planck analysis alone which gives $r<0.13$ (95% c.l.). The estimated amplitude of the dust polarization power spectrum agrees with expectations for this field based on both HI column density and Planck polarization measurements at 353 GHz in the BICEP2 field. Including the latter constraint in our analysis improves the limit further to $r < 0.09$, placing strong constraints on inflation (e.g., models with $r>0.14$ are excluded with 99.5% confidence). We address the cross-correlation analysis of BICEP2 at 150 GHz with BICEP1 at 100 GHz as a test of foreground contamination. We find that the null hypothesis of dust and lensing with $r=0$ gives $\Delta \chi2<2$ relative to the hypothesis of no dust, so the frequency analysis does not strongly favor either model over the other. We also discuss how more accurate dust polarization maps may improve our constraints. If the dust polarization is measured perfectly, the limit can reach $r<0.05$, but this degrades quickly to almost no improvement if the dust calibration error is 20% or larger or if the dust maps are not processed through the BICEP2 pipeline, inducing sampling variance noise. (Abridged.)

Summary

No one has generated a summary of this paper yet.

Paper to Video (Beta)

No one has generated a video about this paper yet.

Whiteboard

No one has generated a whiteboard explanation for this paper yet.

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Continue Learning

We haven't generated follow-up questions for this paper yet.

Collections

Sign up for free to add this paper to one or more collections.