Papers
Topics
Authors
Recent
Search
2000 character limit reached

Generation of abdominal synthetic CTs from 0.35T MR images using generative adversarial networks for MR-only liver radiotherapy

Published 13 Aug 2019 in physics.med-ph and eess.IV | (1908.04809v1)

Abstract: Electron density maps must be accurately estimated to achieve valid dose calculation in MR-only radiotherapy. The goal of this study is to assess whether two deep learning models, the conditional generative adversarial network (cGAN) and the cycle-consistent generative adversarial network (cycleGAN), can generate accurate abdominal synthetic CT (sCT) images from 0.35T MR images for MR-only liver radiotherapy. A retrospective study was performed using CT images and 0.35T MR images of 12 patients with liver (n=8) and non-liver abdominal (n=4) cancer. CT images were deformably registered to the corresponding MR images to generate deformed CT (dCT) images for treatment planning. Both cGAN and cycleGAN were trained using MR and dCT transverse slices. Four-fold cross-validation testing was conducted to generate sCT images for all patients. The HU prediction accuracy was evaluated by voxel-wise similarity metric between each dCT and sCT image for all 12 patients. dCT-based and sCT-based dose distributions were compared using gamma and dose-volume histogram (DVH) metric analysis for 8 liver patients. sCTcycleGAN achieved the average mean absolute error (MAE) of 94.1 HU, while sCTcGAN achieved 89.8 HU. In both models, the average gamma passing rates within all volumes of interest were higher than 95% using a 2%, 2 mm criterion, and 99% using a 3%, 3 mm criterion. The average differences in the mean dose and DVH metrics were within +/-0.6% for the planning target volume and within +/-0.15% for evaluated organs in both models. Results demonstrated that abdominal sCT images generated by both cGAN and cycleGAN achieved accurate dose calculation for 8 liver radiotherapy plans. sCTcGAN images had smaller average MAE and achieved better dose calculation accuracy than sCTcyleGAN images. More abdominal patients will be enrolled in the future to further evaluate two models.

Citations (30)

Summary

No one has generated a summary of this paper yet.

Paper to Video (Beta)

No one has generated a video about this paper yet.

Whiteboard

No one has generated a whiteboard explanation for this paper yet.

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Continue Learning

We haven't generated follow-up questions for this paper yet.

Collections

Sign up for free to add this paper to one or more collections.