High precision proton beam monitor system concept design on CSNS based on SiC

Published 14 Mar 2024 in physics.acc-ph and physics.ins-det | (2403.09244v1)

Abstract: A high precision beam monitor system based on silicon carbide PIN sensor is designed for China Spallation Neutron Source 1.6 GeV proton beam to monitor the proton beam fluence.The concept design of the beam monitor system is finished together with front-end electronics with silicon carbide PIN sensors, readout system and mechanical system.Several tests are performed to study the performance of each component of the system.The charge collection of the SiC PIN sensors after proton radiation is studied with 80 MeV proton beam for continuous running. Research on the performance of the front-end electronics and readout system is finished for better data acquisition.The uncertainty of proton beam fluence is below 1% in the beam monitor system.