Papers
Topics
Authors
Recent
Search
2000 character limit reached

Joint image reconstruction and segmentation of real-time cardiac MRI in free-breathing using a model based on disentangled representation learning

Published 13 Sep 2024 in eess.IV, cs.CV, and physics.med-ph | (2409.08619v1)

Abstract: A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed method in undersampled real-time acquisitions based on an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation. Images and predicted LV segmentations were compared to the reference standard of ECG-gated segmented Cartesian cine in repeated breath-holds and corresponding manual segmentation. On a 5-point Likert scale, image quality of the real-time breath-hold approach and Cartesian cine was comparable in healthy participants (RT-BH: 1.99 $\pm$ .98, Cartesian: 1.94 $\pm$ .86, p=.052), but slightly inferior in free-breathing (RT-FB: 2.40 $\pm$ .98, p<.001). In patients with arrhythmia, image quality from both real-time approaches was favourable (RT-BH: 2.10 $\pm$ 1.28, p<.001, RT-FB: 2.40 $\pm$ 1.13, p<.001, Cartesian: 2.68 $\pm$ 1.13). Intra-observer reliability was good (ICC=.77, 95%-confidence interval [.75, .79], p<.001). In functional analysis, a positive bias was observed for ejection fractions derived from the proposed model compared to the clinical reference standard (RT-BH mean EF: 58.5 $\pm$ 5.6%, bias: +3.47%, 95%-confidence interval [-.86, 7.79%], RT-FB mean: 57.9 $\pm$ 10.6%, bias: +1.45%, [-3.02, 5.91%], Cartesian mean: 54.9 $\pm$ 6.7%). The introduced real-time MR imaging technique is capable of acquiring high-quality cardiac cine data in 1-2 minutes without the need for ECG gating and breath-holds. It thus offers a promising alternative to the current clinical practice of segmented acquisition, with shorter scan times, higher patient comfort and increased robustness to arrhythmia and patient incompliance.

Summary

No one has generated a summary of this paper yet.

Paper to Video (Beta)

No one has generated a video about this paper yet.

Whiteboard

No one has generated a whiteboard explanation for this paper yet.

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Continue Learning

We haven't generated follow-up questions for this paper yet.

Collections

Sign up for free to add this paper to one or more collections.