Development of hafnium-based transition edge sensor bolometers for cosmic microwave background polarimetry experiments

Published 8 Oct 2024 in physics.ins-det and astro-ph.IM | (2410.06227v1)

Abstract: Next generation cosmic microwave background (CMB) polarimetry experiments aim to deploy order 500,000 detectors, requiring repeatable and reliable fabrication process with stable and uniform transition edge sensor (TES) bolometer performance. We present a hafnium (Hf)-based TES bolometer for CMB experiments. We employ a novel heated sputter deposition of the Hf films enabling us to finely tune the critical temperature (Tc) between 140 mK - 210 mK. We found elevated deposition temperatures result in films with lower stress, larger crystal sizes, and a smaller relative abundance of the m-plane to c-plane $\alpha$ phase, all contributing to the empirical linear dependence of critical temperature on deposition temperature. Crucially, the heated sputter deposition simultaneously ensures that the critical temperature does not drift despite exposure to heat throughout ongoing fab processes (sometimes reaching 350C) as long as the initial deposition temperature is not exceeded. Tcs lower than 170 mK require deposition temperature greater than 400C, far in excess of typical temperatures the wafer may experience. This ample thermal budget allows us to relax the stringent thermal management that conventional aluminum manganese (AlMn) TES bolometers require, for which temperatures as low as 200C - 250C are used to anneal the AlMn in an effort to adjust the Tc. Hf additionally exhibits an intrinsic steep superconducting transition (we measure $\alpha >$ 200) and a corresponding high loop gain (exceeding $\mathcal{L}>10$ deep in the transition). We precisely design the normal resistance of the TES to range between 10 milli-Ohm and 1 Ohm through an interdigitated geometry, making these TES bolometers compatible with both TDM, FDM, and $\mu$-mux readout systems. We report on bolometer parameters including critical temperature, normal resistance, saturation power, time constant, and loop gain.

Summary

No one has generated a summary of this paper yet.

Paper to Video (Beta)

No one has generated a video about this paper yet.

Whiteboard

No one has generated a whiteboard explanation for this paper yet.

Open Problems

We haven't generated a list of open problems mentioned in this paper yet.

Continue Learning

We haven't generated follow-up questions for this paper yet.

Collections

Sign up for free to add this paper to one or more collections.

Tweets

Sign up for free to view the 1 tweet with 0 likes about this paper.