2000 character limit reached
X-ray diffraction characterization of suspended structures for MEMS applications
Published 10 Jan 2025 in cond-mat.mtrl-sci, physics.app-ph, and physics.class-ph | (2501.10424v1)
Abstract: Mechanical stress control is becoming one of the major challenges for the future of micro and nanotechnologies. Micro scanning X-ray diffraction is one of the promising techniques that allows stress characterization in such complex structures at sub micron scales. Two types of MEMS structure have been studied: a bilayer cantilever composed of a gold film deposited on poly-silicon and a boron doped silicon bridge. X-ray diffraction results are discussed in view of numerical simulation experiments.